Error Wrong data storage format 1C 8.3

A feature of this error is that the error is not detected for everyone, but for individual users.

The reason for this kind of error is a problem in the 1C cache.

Cache data is stored exactly on each individual user's computer. Incorrect operation of the 1C cache can occur due to software errors, when a computer crashes, when the power of a running PC is turned off, etc.

The cache is an intermediate buffer with temporary files that the program uses for various calculations. Caching is used to speed up the performance of the 1C program.

Let's consider how to fix the error Wrong data storage format 1C 8.3 and clear the 1C cache in several ways.

Ways to fix the error

First way. Clearing the 1C cache manually

To do this, we find the address of the directory with temporary files 1C. They can be viewed in the launch settings of 1C databases.

Step 1. Open the list of bases - the Settings button:

Step 2 Having opened the specified directory, we will see a list of folders in which temporary files are stored. The number of folders depends on the number of installed 1C configurations.

Step 3 To clear the 1C cache, go to the location of temporary files and delete these folders. Before deleting folders with 1C cache, you need to close infobases. Otherwise, only inactive caches of past periods will be deleted:

The second way. Removing a database from the list and reconnecting it

Step 1. We open the list of bases from the launch of 1C. Delete the installed configuration, for example, BOOM 3.0 Classic, after remembering the place where it is located:

To the question "Remove information base from the list: Yes/No? answer "Yes":

Step 2 We connect the base to the list of bases again. Add button – Adding an existing infobase to the list:

Step 3 In the path of finding the base, specify the location of the base BOOM 3.0 Classic:

When the database is reconnected to the list of databases, a new folder with a clean 1C cache is created.

The disadvantage of the second method is that corrupted temporary files are not deleted with hard drive and take up space.

The third way. ClearCache

When setting up an infobase, in the line Additional launch options, specify the /ClearCache command. This command clears the 1C cache, but the program slows down:

The /ClearCache command clears the 1C cache of Client-Server requests, respectively, the data for the Thick client and Thin client are deleted. It should also be noted that this way not suitable for the Local 1C metadata cache.


Rate this article:

If 1C: Enterprise 8 does not start and the program gives an error - “Invalid data storage format”, then you should not panic. Let's consider the solution of this problem on a live example. To defeat this error, first of all, you need to identify the reason that caused this behavior of the 1C: Enterprise 8 program.

Identification of the causes of the error 1C Enterprise 8

On a note: if the recommendations below are incomprehensible to you, and the error needs to be corrected, I urgently recommend contacting us - Smart1С.ru.

The accountant told me that yesterday, on the eve of the end of the working day, she made the completion Windows work, and the computer did not want to turn off and had to unplug the 220 V power supply from the outlet. Then I began to think ... And what came to mind:

  • Due to improper shutdown of the PC, files on HDD not registered correctly.
  • Another thought came up that we still need to google this information. After all, due to incorrect completion, platform files can also be damaged.

Actions after viewing the 1C data format error

I started looking for this error about the wrong data format in search engines on the Internet. Searching, I found out the following - it turns out, given error not as trivial as it initially seems. But, after reading articles on this topic on the forums, I learned recommendations that you need to clean temporary files - cache 1C: Enterprise 8.

Information on the cache 1C. Cache 1C Enterprise 8 is an area on the computer where the 1C Enterprise 8.3 platform saves files with various service information. They wrote on the Internet that incorrect data in the cache may appear, for example, when the electricity is turned off while data is being written, since part of the data in this case will not be written, hence the glitch appears. Clearing the cache 1C Enterprise 8 with such errors, along with testing and fixing the database, are the main service functions that restore the program's performance.

I did not want to manually clean temporary files, I decided to look for a script designed for this purpose. I climbed a little on the forums and found a bat file, looked at its test content (there were commands for deleting files and folders of the 1C platform from the user profile), then double-clicked to launch it (see the contents of the script below).

After the bat nickname was completed and closed, I tried to run the 1C program again - this time a window appeared with the choice of the 1C user, and after the 1C authentication procedure, the 1C program itself. Mission accomplished!

Bat-file for cleaning the cache 1C Enterprise 8

It would be unreasonable to simply give you a bat-file for cleaning the 1C cache without considering its contents, the commands present in it. So what do these commands mean command line Windows:

del /s /q %userprofile%\AppData\Local\1C\*.*

rd /s /q %userprofile%\AppData\Local\1C\

del /s /q %userprofile%\AppData\Roaming\1C\1cv8\*.*

rd /s /q %userprofile%\AppData\Roaming\1C\1cv8\

del /s /q %userprofile%\AppData\Roaming\1C\1cv82\*.*

rd /s /q %userprofile%\AppData\Roaming\1C\1cv82\

Copy commands to text file opening Notepad, then "Save As" and give the file a name, specifying the extension. For example, - "cache.bat".

My explanations - the @echo off command turns off the output of data to the screen, the del command deletes files from the specified folder, * means all files, the command deletes folders. I think the rest of the content is quite clear to you, and if not, write to me in the VK group, I will try to explain or I can help in resolving the issue remotely (for a fee, through TeamViewer). The specified file can be run in all Windows versions, also in the new Windows 10.

I also want to say that cleaning the 1C cache helps even in cases where the program 1C starts and immediately crashes, so take the bat-file into service.

This life hack to solve the issue of the incorrect format of the data warehouse 1C Enterprise 8 is completed. If you have any questions or something could not be done, I recommend that you contact by mail This address Email protected from spam bots. You must have JavaScript enabled to view. .

If due to your professional activity you have to work with the 1C program, you might already have had the sad experience of some problems, which you still managed to solve by fiddling for some time. However, many are thrown into a real shock by the situation in which the program simply refuses to work correctly. No matter how hard you try to force it to perform some actions, a shocking 1C error message “Invalid data storage format” stubbornly appears on the screen.

An invalid data store format error occurs due to a cache failure.

Some users are especially ready to associate such a situation with a disaster, when urgent work is to be done, and no one around can help fix the problem. Indeed, the error "Invalid 1C storage format" does not occur for all users who have to work with this program. It is for this reason that the "victims" begin to wonder what they did wrong, which could lead to such a software failure.

In fact, the reason why the error occurs in 1C 8 “Invalid data storage format” is a problem closely related to data caching in the program itself.

So, having received information that the error “Invalid data storage format” in 1C is provoked by the incorrect operation of the 1C cache. Now it is easy to understand why such a fate awaits only one or a few PCs out of the total number on which this program is installed. A 1C cache failure occurs if, at the time of working with the program, while updating it, the power supply is suddenly turned off, as a result of which the program.

The cache is considered as a temporary storage in which files are placed that are necessary to ensure the speed of any software, opening Internet pages. The 1C program is no exception. It also successfully saves in this cached space some of the files that speed up the calculation processes. If a failure occurs in it, the program cannot cope with it on its own, some cached files catastrophically interfere with it.

It is for this reason that it is useful to know what to do to get the software up and running without getting nervous or wasting a lot of valuable time.

Clearing the 1C cache manually

It is easy to guess that if the reason lies in the cache, then you should put things in order in it. Open the folder where these temporary files are stored and just clear it. Of course, for some, such actions will not seem simple, so we recommend that you follow this route. First, run the program, then find the "Settings" button in it, located on the right side of the open dialog box.

After you click on this button, a new window will open, in which folders will be displayed, in which temporary files are concentrated. Do not be alarmed if there are several such folders. Their number directly depends on how many configurations you installed on this computer.

Now you just have to follow the path that the program itself has shown you. Having reached the goal, having found a storage with temporary files, do not rush to delete them all at once. First close the program, and only then delete it. Otherwise, if you forgot to close the infobases, you can manually delete only those caches that were previously used. Active files used by open infobases will remain on your PC.

Removing a database from the list and reconnecting it

If 1C does not start due to the error "Invalid data storage format", try clearing the list of databases that you previously installed. It is not difficult to do such actions, first open the entire list of databases, then select the one you want to delete. Do not rush to click on the "Delete" button. Lower your gaze down the open window, the path will be indicated there, where the base with which you are in is saved. this moment want to "break up". Now, when you remember this path, press the "Delete" button, confirm your decision. This completes the removal of the allegedly problematic database.

Now you will have to return it back, because without it you will not be able to perform some of the functions assigned to you. Find the "Add" button, click on it, in the new window that pops up, select the second option "Add to the list of an existing infobase". Next, you will need to specify the path where this database is saved. After such manipulations, a clean folder will be created to save the 1C cache.

Unfortunately, sometimes it is difficult to delete some temporary files, so you have to put up with their "existence", which negatively affects the number free space on the disk space your PC.

If you go to the infobase settings, you can set the ClearCache command there as additional options launch. In this case, the program will automatically clear the cache, but, unfortunately, you will have to forget about the speed of this software. Also, you should definitely take into account that ClearCache can delete all Tolstoy data and Thin clients, but at the same time it is absolutely not suitable for the Local 1C metadata cache.

So, do not be afraid every time a problem arises when working with software, including 1C. With a little digging, you can find successful instructions from those who have already encountered such problematic points, so they know how to fix them.

In today's article I will tell you what to do in such a situation: you launched the program 1C Enterprise, then the process of updating the version of the program began and suddenly it is interrupted with an error message: “ Failed to update. Wrong data store format”:

In fact, there is nothing wrong with this error, and most often it is fixed quite simply - just clear cache 1C . I tell you how to do it:

1. Close the program first 1C, and make a backup of the database just in case. To do this, go to the folder where the database is stored and copy the file somewhere 1Cv8.1CD:

2. Now we need to find out in which folder are stored temporary files of the program 1C. To do this, run the program again 1C:Enterprise. In the start window, select the name of your infobase and click the “ Setting”:

In the window that opens, we see the path where 1C temporary files are stored. I have the following path: C:\Users\VLADIMIR\AppData\Roaming\1C\1cv8\tmplts:

The cache folders will be located at C:\Users\VLADIMIR\AppData\Roaming\1C\1cv8. In your case, the path might be: .

3. So, close 1C. Then Windows tools go to folder C:\Users\UserName\AppData\Roaming\1C\1cv8(if you don't see the folder AppData then read the first comment under this article). Here we select all folders with alphanumeric long names and boldly delete them:
After deleting the folders, we launch the 1C Enterprise program again. This time, the program update should be successful and the “Invalid datastore format” error should not occur again.

Probably, it is rare to meet a person who often works with the 1C 8.3 (or 8.2) program and has not met with a window with an inscription of this kind: “ Wrong datastore format ‘file://C:/Users/Alex1/AppData/Local/1C/1cv8/058t1 m89-295c-47c4-8922-f67f568rf70e /Config/RuntimeCacheStorage' «.

Most often, such an error appears when updating the configuration, when opening processing, in the configurator, and in other cases. The reason lies either in the violation of the integrity of the infobase structure, or - more often - in the 1C cache.

Let's take a look at how to fix it. And there may be several options. I will list them as the complexity of the actions increases, and then I will describe in more detail:

  • clearing the cache;
  • fixing the database structure;
  • data transfer to a clean, not "broken" infobase.

Get 267 1C video lessons for free:

As you probably already guessed, this option will help fix the error only if it is related to problems in the local cache. You can easily find information on how to clear the local cache on the Internet. A lot has already been written about this (including in our article :), and I will not repeat myself.

Sometimes it is enough to remove the line with the name of the infobase from the list, and then add it again. This will create a new, clean folder for the cache. Often I do not recommend using this method, since the folder with the old cache remains and clogs the disk.

Fixing the database structure

At this stage, we must first try regular mechanisms testing and fixing the database. This applies both to the launch of the corresponding item in the configurator and to the launch of the .

But practice shows that these mechanisms do not always help.

Then we proceed as follows. We develop a clean information base. The goal is to get a configuration file (with the cf extension).

Then we remove the non-working configuration from support and merge with the saved cf file. If required, we combine with the restoration of support. Don't forget to make a backup before doing this!

Important! When merging with a clean generic configuration, changes made previously to your configuration may be lost. You will need to add them again. Be careful!

Transferring data to a clean, not "broken" infobase